Skip to main content

Establishment profile

VI WATER AND POWER AUTHORITY

#1 ESTATE RICHMOND, CHRISTIANSTED, VI, 00820
Operated by V.I. Water & Power Authority · 1 of 8 establishments
221112Fossil Fuel Electric Power Generation

Download as PDF →

OSHA inspections
13
over 46 years
Violations
32
SVEP
YES
Severe violator program
Accident investigations on record
2 hospitalizations · 2 National Emphasis Program inspections · 1 OSHA follow-up

Summary

VI WATER AND POWER AUTHORITY has accumulated 32 OSHA violations across 13 inspections over 46 years of recorded history.

The establishment sits in the 94th percentile for violations within its industry-state peer group of 17 employers. Inspection frequency runs at the 94th percentile. The most recent enforcement activity was recorded 11 years ago.

Federal records were found in 1 of 15 sources. Sources without matching records returned empty for this establishment.

Agency coverage

VI WATER AND POWER AUTHORITY appears in OSHA workplace safety record only. No matching records were found in WHD wage enforcement, MSHA mine safety, EPA environmental compliance, NLRB labor relations, OFLC visa and labor certification (historical), FMCSA motor carrier registration, SAM.gov federal debarment, CMS nursing home enforcement, UVA Corporate Prosecution Registry, CPSC product recalls, or NHTSA vehicle recalls. Single-agency enforcement records typically indicate either a discrete incident-based inspection or a low-risk operational profile.

OSHA workplace safety

Inspections
13
0.3 / yr · last 46 yrs
Violations
32
0.7 / yr
Penalties
$0
56% serious44% other
Inspection trigger · complaint
6 of 13
Inspection trigger · planned
5 of 13

31% of inspections at this establishment produced violations, with 3 inspections producing serious-or-greater violations.

Most-cited OSHA standards

Top OSHA standards cited at this employer, ranked by citation count. Standards (CFR sections) cluster citations into safety themes -- machine guarding, lockout-tagout, hazard communication, fall protection, process safety, etc. A concentration on one or two sections reveals a pattern that individual citations don’t. 20 distinct standards shown · 25 citations in this view.

CFR sectionCitationsInspectionsTotal penaltyFirst citedLast cited
29 CFR 1910.0157 G0122Aug 1989Apr 2008
29 CFR 1910.0157 C0122Sep 1989Apr 2008
29 CFR 1910.0157 C0422Sep 1989Nov 1997
29 CFR 1910.0037 Q0122Aug 1989Sep 1989
29 CFR 1910.0305 B0222Aug 1989Sep 1989
29 CFR 1910.1200 H0111Apr 2008Apr 2008
29 CFR 1910.0036 D0111Apr 2008Apr 2008
29 CFR 1910.0037 B0211Apr 2008Apr 2008
29 CFR 1910.0132 E11Apr 2008Apr 2008
29 CFR 1910.0303 G02 I11Apr 2008Apr 2008
29 CFR 1910.1200 E0111Apr 2008Apr 2008
29 CFR 1910.1200 G0811Apr 2008Apr 2008
29 CFR 1904.0029 A11Apr 2008Apr 2008
29 CFR 1910.0269 D07 IV11Nov 1997Nov 1997
29 CFR 1910.0269 A02 I11Nov 1997Nov 1997
29 CFR 1910.0269 D02 VI11Nov 1997Nov 1997
29 CFR 1910.0269 D0511Nov 1997Nov 1997
29 CFR 1910.0269 D07 II11Nov 1997Nov 1997
29 CFR 1910.0151 C11Sep 1989Sep 1989
29 CFR 1910.0037 K0211Sep 1989Sep 1989

Source: OSHA inspection citations (violation_detail). CFR section codes can be looked up at osha.gov/laws-regs for the formal standard text. Per-inspection detail and the specific violation descriptions are available by expanding individual inspections below.

Peer comparison

94th

Worse on violations than most other employers in NAICS 2211 within VI. Peer group: 17 employers. This establishment has 32 OSHA violations; peer median is 4.

Fewer violationsMore violations
Penalty percentile
0th
peer median: $0
Inspection frequency
94th
peer median: 1

Safety self-report (OSHA 300A)

Recordable injury rates the employer filed with OSHA’s Injury Tracking Application. DART covers cases with days away, restricted, or transferred; TRIR is the total recordable case rate.

DART rate
1.9
vs industry
+0.5
TRIR
1.9
vs industry
−0.4

Reported for 265 average annual employees at this establishment.

Source: OSHA ITA Form 300A (employer self-reported). Rates are per 100 full-time equivalent workers. Establishments below the ~10-FTE threshold are not required to report.

Industry benchmark

Industry avg TRIR
2.3
BLS SOII 2024
Industry avg DART
1.4
BLS SOII 2024
Self-reported TRIR
1.9
OSHA ITA Form 300A (employer self-reported)

BLS rates reflect industry-wide averages. Self-reported figures come from OSHA’s Injury Tracking Application; absence of self-reported data does not necessarily indicate non-compliance — many establishments fall below the ITA reporting threshold.

Inspection breakdown

Planned
5
Complaint
6
Accident
1
Follow-up
1

Complaint- and accident-triggered inspections are stronger risk signals than routine planned inspections.

OSHA severe injury reports

No severe injury reports (hospitalization, amputation, or loss of an eye) on file under 29 CFR 1904.39 for VI WATER AND POWER AUTHORITY. Verify directly with Occupational Safety and Health Administration

OSHA accident events

Accidents, fatalities, and catastrophes documented during OSHA inspections at this employer. Each entry links to the inspection that recorded it.

DateEventInjuriesHospitalizedFatalities
May 9, 1997BURN,ELECTRIC ARC,ELECTRICAL,FIRE,E PTD,ELEC UTILITY WORK,ELECTRICAL FAULT,TRANSFORMER22

Source: OSHA accident investigations. Narratives are recorded by the inspecting officer and may be truncated.

Activity timeline

Data refreshed
Weekly
First OSHA inspection
Most recent activity
11 years ago

No federal enforcement activity has been recorded against this establishment in 11+ years. Most recent activity: 11 years ago. Data on this page is refreshed weekly.

Wage & Hour Division (WHD)

No WHD wage, overtime, or child-labor enforcement cases on file for VI WATER AND POWER AUTHORITY. Verify directly with Wage and Hour Division

Mine safety (MSHA)

No MSHA mine safety violations on file for VI WATER AND POWER AUTHORITY. Verify directly with Mine Safety and Health Administration

Labor relations (NLRB)

No NLRB unfair labor practice charges or union representation cases on file for VI WATER AND POWER AUTHORITY. Verify directly with National Labor Relations Board

Visa & labor certification (OFLC) — historical

No H-1B, H-2A, or H-2B labor condition applications on file (historical data only — DOL ended OFLC publication) for VI WATER AND POWER AUTHORITY. Verify directly with Office of Foreign Labor Certification

Environmental compliance (EPA)

No EPA inspections or formal enforcement actions on file for VI WATER AND POWER AUTHORITY. Verify directly with Environmental Protection Agency

Federal criminal prosecution record

No federal criminal prosecutions, plea agreements, or deferred-prosecution agreements on file for VI WATER AND POWER AUTHORITY. Verify directly with UVA Corporate Prosecution Registry

Inspection history

DateTriggerViolationsSeriousPenalty
2015-06-05Complaint0$0
2008-03-04Complaint106$0
2006-04-20Planned0$0
1999-02-11Complaint0$0
1997-05-09Accident66$0
1994-05-18Complaint0$0
1990-08-01Follow-up0$0
1989-08-18Planned126$0
1989-08-16Planned4$0
1987-03-20Planned0$0
1986-05-22Complaint0$0
1985-02-26Complaint0$0
1979-09-18Planned0$0

Source: OSHA IMIS. Citation amounts reflect initially assessed penalties; final amounts after appeal may differ.

In the news

Part of a larger organization

VI WATER AND POWER AUTHORITY is one of 8 establishments rolled up under the parent organization V.I. Water & Power Authority.

Federal enforcement records on this page represent activity at this specific establishment only. The full enforcement footprint of V.I. Water & Power Authority across all 8 of its tracked locations is viewable on the parent profile.

Other employers in this industry and state

Other employers in fossil fuel electric power generation within VI, ordered by federal enforcement volume:

Other locations under this parent

Other establishments operated by V.I. Water & Power Authority, ordered by federal enforcement volume:

Related searches

About this data

This profile aggregates federal enforcement records on VI WATER AND POWER AUTHORITY from every major federal compliance and enforcement source plus the UVA Corporate Prosecution Registry. OSHA workplace safety inspections, WHD wage cases, MSHA mine safety, EPA environmental enforcement, NLRB labor relations, OFLC visa/labor certification, FMCSA motor carrier registration, SAM.gov debarments, CMS nursing-home records, BLS industry safety benchmarks, OSHA ITA self-reported injury rates, SEC enforcement and financial disclosures, CPSC and NHTSA recalls.

Establishments are matched across agencies using normalized employer name, state, and ZIP code. This establishment resolves to the parent rollup V.I. Water & Power Authority, which operates 8 establishments in our dataset.

OSHA citations typically appear 3–8 months after the inspection, so very recent enforcement actions may not yet be reflected. Profiles may be incomplete if the establishment operates under multiple legal names or files under variations our entity-matching rules don’t yet cover. To report a missing record or correction, email corrections@fastdol.com.

Need API access, bulk download, or licensed redistribution? The website is free. Programmatic and licensed access is handled separately.

Contact sales →

Frequently asked

What is VI WATER AND POWER AUTHORITY's OSHA violation history?
VI WATER AND POWER AUTHORITY has 13 OSHA inspections on record with 32 violations and $0 in total penalties.
How does VI WATER AND POWER AUTHORITY's safety record compare to its industry?
VI WATER AND POWER AUTHORITY operates in the fossil fuel electric power generation industry. The industry average Total Recordable Incident Rate (TRIR) is 2.3. VI WATER AND POWER AUTHORITY's self-reported DART rate is 1.93 compared to an industry average of 1.4.